Isolation Transformer
Isolation Transformers are effective and sensitive equipment which save from Line Voltage Transients, Spike & DC Leakage etc. They are specially designed for sensitive critical equipments like computers & peripharels, medical instrumenttion digital communication telemetry systems, CNC Machines etc. and stopping such disturbance generated by the equipments load from being injected into the power line.
Isolation Transformer is a transformer Used to transfer electrical power from a source of alternating current (AC) power to some equipment or device while isolating the powered device from the power source, usually for safety reasons. Isolation transformers provide galvanic isolation; no conductive path is present between the source and load. This isolation is used to protect against electric shock to suppress electrical noise in sensitivity with special insulation between primary and secondary and is specified to withstand a high voltage between windings.
Isolation transformers block the transmission of the DC component in signals from one circuit to the other but allow AC components in signals to pass. Transformers that have a ratio of 1 to 1 between the primary and secondary windings are often used to protect secondary circuits and individuals from electrical shocks between energized conductors and the earth’s ground. Suitably designed Isolation transformers block interference caused by ground loops. Isolation transformers with electrostatic shields are sued for power supplies for sensitive equipment such as computers, medical devices, or laboratory instruments.


SPECIFICATIONS
Capacity | 1 KVA to 1500 K |
Phase | Single Phase and Three Phase |
Input Voltage | 220,230V in Singal Phase. 400V, 415V in Three Phase |
Output Voltage | 220,230V in Singal Phase. 400V, 415V in Three Phase or as per requirement |
Frequency | 50 Hz |
Transformer Ratio | 1:1 (as per requirement) |
Type | Indoor |
Vector Group | DYN 11 (as per requirement) |
Winding | Copper Winding |
Lamination | CRGO |
% Impedance | 5% |
Type of Cooling | Natural Air/ Oil Cooled |
Ambient Temperature | 1 Degree to 55 Degree C |
Power Factor | 0.75 Lag to Lead |
C.M.N.R. | 100 db |
Class of Insulation | Class B to H |
Insulation Resistance | More than 100 M Ohms |
Coupling Capacitance | Less than 0.01 pF |
VI Electric Strength | 2500V AC for 120 Sec |
Over Load Capicity | 110% for 10 Minutes |
Duty Cycle | Continuous |
Efficiency | Better than 97% |
IS Confirming to | IS : 2026 |
Termination | All Input & Output Terminals Brought out on a terminal board through studs of adequate rating. |
Features
- High quality lamination and conductors ensure Low Losses Phase
- Impregnated with International Quality Resins and Varnishes
- Designed with windings to reduce overall capacitance of the winding
-
Terminals are shrouded for safety
- Chemically treated & plated hardware to avoid corrosion
- The efficiency of the transformer is high due to low dissipation of heat energy.
Application
- Printing Machinery
- CNC Machinery, Laser Engravers
- Textile Machinery
-
Hospital Facilities